VINZENZ GRUPPE
     
 

Efficacy and safety of a new low-volume PEG with citrate and simethicone bowel preparation for colonoscopy (Clensia): a multicenter randomized observer-blind clinical trial vs. a low-volume PEG with ascorbic acid (PEG-ASC).

Kump, Patrizia, Hassan, Cesare, Spada, Cristiano, Brownstone, Eva, Datz, Christian, Haefner, Michael, Renner, Friedrich, Schoefl, Rainer und Schreiber, Florian (2018) Efficacy and safety of a new low-volume PEG with citrate and simethicone bowel preparation for colonoscopy (Clensia): a multicenter randomized observer-blind clinical trial vs. a low-volume PEG with ascorbic acid (PEG-ASC). Endoscopy international open, 6 (8). E907-E913. ISSN 2364-3722

Für diesen Eintrag wurde kein Volltext-Dokument angefügt.

Kurzfassung

Background and study aims  Quality of inspection during colonoscopy is strictly related to the level of cleansing. High-volume (PEG-based) solutions are highly effective and safe, but their high volume affects tolerability and compliance. The aim of this study was to compare a new low-volume PEG with citrate and simethicone solution (PMF 104,Clensia) with a low-volume PEG with ascorbic acid solution (PEG-ASC; Moviprep). Patients and methods  This was a multicenter, randomized, observer-blind, parallel-group, phase 3 clinical trial, where patients were randomized between PMF 104 and PEG-ASC. In both groups, patients were instructed to take a full-dose regimen the evening before if colonoscopy was scheduled before 11 am to 12 pm, or to take a split regimen if colonoscopy was scheduled after 11 am to 12 pm. The primary end-point was an equivalence between PMF104 and PEG-ASC in the rate of adequate level of cleansing (Ottawa scale ≤ 6), with safety, mucosal visibility, tolerability, acceptance and compliance being also assessed. Results  Of the 403 enrolled, 367 patients (Mean age [SD]: 55.6 (14.4) years; male:166 [45.2 %]) were included in the per protocol (PP) analysis: 184 being randomized in the PMF 104 group and 183 in the PEG-ASC group. Successful bowel cleansing was 78.3 % and 74.3 % in PMF104 and in PEG-ASC, respectively ( <i>P</i>  = 0.37). Both preparations were equally safe (mild adverse events were observed in 9.2 % and 9.3 % of patients in the PMF104 and in the PEG-ASC group, respectively) and acceptable (no or mild distress during the intake in 81.4 % and 80.8 % in the PMF104 in the PEG-ASC, respectively [ <i>P</i>  = 0.74]). Conclusion  The new low-volume product Clensia is equivalent to the reference low-volume PEG-ASC in terms of bowel cleansing, safety and acceptance.
Typ des Eintrags: Artikel
Bereiche: Ordensklinikum Linz Barmherzige Schwestern > Interne IV: Gastroenterologie & Hepatologie, Endokrinologie und Stoffwechsel, Ernährungsmedizin
Benutzer: Prof. Dr. Rainer Schöfl
Hinterlegungsdatum: 16 Nov 2021 11:40
Letzte Änderung: 16 Nov 2021 11:40
URI: https://eprints.vinzenzgruppe.at/id/eprint/9311

Actions (login required)

Eintrag anzeigen
Eintrag anzeigen