. 2024 Jun 5;106(11):941-949.
doi: 10.2106/JBJS.23.00526. Epub 2024 Mar 21.

Three-Dimensional Osseointegration Patterns of Cementless Femoral Stems: An ex Vivo Study with High-Resolution Imaging and Histological Evaluation

Affiliations

Three-Dimensional Osseointegration Patterns of Cementless Femoral Stems: An ex Vivo Study with High-Resolution Imaging and Histological Evaluation

Gilbert M Schwarz et al. J Bone Joint Surg Am. .

Abstract

Background: Osseointegration is essential for the long-term survival of cementless femoral stems and is dependent on periprosthetic bone quality and correct implantation technique. The aim of this study was to evaluate the 3-dimensional long-term fixation patterns of, and bone microarchitecture around, cementless hip stems.

Methods: Four specimens with varying degrees of bone quality and fixation characteristics from body donors who had received Alloclassic Zweymüller hip stems during their lifetime (mean time in situ at the time of death: 12.73 years) were evaluated with use of radiographs, high-resolution computed tomography (CT) scans, and hard-tissue histology. The CT voxel size was 85 µm, and the following parameters were calculated: total bone volume, total bone volume fraction, trabecular bone volume, trabecular bone volume fraction, cortical bone volume, cortical bone volume fraction, and cortical thickness. Bone-implant contact and canal fill index values for each Gruen zone of the specimens were calculated with use of histological samples.

Results: Femoral stems with apparently good cortical contact on clinical radiographs showed higher values for cortical bone volume, trabecular bone volume, and cortical thickness in the high-resolution CT analysis than femoral stems with apparently weak cortical contact on clinical radiographs. Based on the histological evaluation, the mean bone-implant contact ranged from 22.94% to 57.24% and the mean canal fill index ranged from 52.33% to 69.67% among the specimens.

Conclusions: This study demonstrated different osseointegration patterns of cementless femoral stems on the basis of radiographs, high-resolution CT scans, and histological evaluation. Femora with high cortical bone volume and cortical thickness were associated with higher canal fill indices, whereas femora with low cortical bone volume and cortical thickness had lower canal fill indices and showed a characteristic corner-anchorage pattern.

Clinical relevance: Osseointegration patterns and thus the long-term survival of cementless femoral stems are dependent on cortical bone volume and cortical thickness.

PubMed Disclaimer

Conflict of interest statement

Disclosure: Part of this work was supported by the project entitled “TIMed 2022++ - Technological Innovation in Medicine 2022++”, which is funded by the Regional Government of Upper Austria. The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article ( http://links.lww.com/JBJS/H947 ).

Similar articles

References

    1. Chanda S, Mukherjee K, Gupta S, Pratihar DK. A comparative assessment of two designs of hip stem using rule-based simulation of combined osseointegration and remodelling. Proc Inst Mech Eng H. 2020 Jan;234(1):118-28.
    1. Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Relat Res. 1986 Jul;(208):108-13.
    1. Fottner A, Woiczinski M, Kistler M, Schröder C, Schmidutz TF, Jansson V, Schmidutz F. Influence of undersized cementless hip stems on primary stability and strain distribution. Arch Orthop Trauma Surg. 2017 Oct;137(10):1435-41.
    1. Laine HJ, Pajamäki KJ, Moilanen T, Lehto MU. The femoral canal fill of two different cementless stem designs. The accuracy of radiographs compared to computed tomographic scanning. Int Orthop. 2001;25(4):209-13.
    1. Zweymüller KA, Lintner FK, Semlitsch MF. Biologic fixation of a press-fit titanium hip joint endoprosthesis. Clin Orthop Relat Res. 1988 Oct;(235):195-206.